BENDIX SD-08-2433 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
COMPRESSOR
DESICCANT
BED
DELIVERY
CHECK
VALVE
PURGE
VALVE
TURBO
CUT-OFF
VALVE
(CLOSED)
CONTROL
PORT
SUPPLY
PORT
FRONT
RESERVOIR
SAFETY
VALVE
REAR
RESERVOIR
PURGE
ORIFICE
OIL
COALESCING
FILTER
CONTROL
LINE
PURGE AIR
EXTENDED
PURGE
PORT
EXHAUST
DELIVERY
PORT
FIGURE 5 - BENDIX
®
AD-9si
AIR DRYER WITHOUT GOVERNOR—PURGE CYCLE
TURBO CUT-OFF FEATURE (Refer to Figures 3
and 5)
The primary function of the turbo cut-off valve is to prevent
loss of engine turbocharger air pressure through the
Bendix
®
AD-9si
air dryer when the dryer is in the purge
mode.
At the onset of the purge cycle, the downward travel of the
purge piston is stopped when the turbo cut-off valve (the
tapered portion of the purge piston) contacts its mating
metal seat in the purge valve housing. With the turbo cut-off
valve seated (in the closed position), air in the compressor
discharge line — as well as the AD-9si air dryer inlet port
— cannot enter the air dryer. By completing these actions,
the turbo cut-off effectively maintains turbocharger boost
pressure to the engine.
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 15 16

Comments to this Manuals

No comments