3. Place the trailer air supply valve in the exhaust position.
The spring brakes should apply. Disconnect the trailer
supply line and apply a soap solution to check for leaks.
A 1" bubble in 5 seconds is permissible.
4. Reconnect the trailer supply hose coupling and
recharge the trailer system. The spring brakes should
release. Shut off the engine. Open the trailer reservoir
drain cock. The tractor air system should bleed down to
approximately 70 psi. The trailer spring brakes should
remain released. After the system is stabilized, leakage
at the open drain cock should not exceed a 1" bubble
in 5 seconds.
5. If the Bendix
®
SR-5
valve does not function as
described; or if leakage is excessive, repair the valve,
or replace with a genuine Bendix service replacement
valve.
REMOVAL
1. Identify and mark or label all air lines and their
connections on the SR-5
valve. Then disconnect the
air lines.
2. Remove the SR-5
valve from the reservoir.
INSTALLATION
1. Install the SR-5
valve on the reservoir.
2. Reconnect all air lines to the valve using the
identi cation made in REMOVAL step 1.
3. Perform OPERATIONAL AND LEAKAGE TESTS before
placing the vehicle back in service.
DISASSEMBLY
The following procedure is for reference only. Always
have the appropriate maintenance kit on hand, and use its
instructions in lieu of those presented here. Refer to Figure
9 throughout the procedure.